| Parameter |
Value |
| Security of the current flowing IEC 62561 |
Electrical and physical continuity from the IONIFLASH® to the earth – Axle 16mm |
| ESEAT / Simple rod Standard deviation |
σ (ESEAT) < 0,28 σ (Simple rod) |
| Lightning strike: IEC 62561 / NFC 17102 (wave 10/350µs) |
Standard Test 100kA 214kA |
| Functioning for positive and negative lightning strikes |
Range of detection of the frequency spectrum of lightning (0 to 10MHz). Self-contained triggering of the leader |
| Early streamer emission spherical technology |
New Generation Patent FR2953337 |
| Reliability of the protection – Repeatability of the answer of the upward leader |
Stability of the laboratory tests and in situ tests (Ampère CNRS / In situ France telecom) |
| Safety in extreme climatic conditions |
Direct electrostatic activation with internal and external double spark gaps |
| Security of the lightning current flowing |
Manufacturing with passed through axle of 16mm diameter |
| Resistance to corrosion |
AISI / Solid 316L stainless steel |
| Testing device |
Checking with IONITEST® device |